Product overview:
The battery forced internal short-circuit test machine is used to simulate the forced internal short-circuit test of the battery under certain environmental temperature conditions. The test box is made of stainless steel, with good temperature uniformity and air exhaust function (i.e. the test exhaust gas is discharged after the test is completed). The control system of the testing machine is PLC touch screen menu operation, and the data collection frequency can reach 100 times / second. At the same time, the test pressure, pressure holding time, measured pressure, battery voltage, battery temperature, voltage drop speed, etc. are programmed by PLC.
Technical parameters of temperature control system:
1. Temperature range: - 10 ℃ ~ 100 ℃
2. Analytical accuracy: 0.1 ℃
3. Temperature fluctuation: ± 0.5 ℃
4. Temperature uniformity: ± 2 ℃
5. Heating rate: 3 ℃ / min
6. Cooling rate: 1 ℃ / min
8. Inner box size: 500x500x600mm (L x W x H)
9. Inner box material: 304 stainless steel plate, bottom reinforced
10. Outer box size: 1050x1500x2100mm (L x W x H)
11. Temperature control system: Guangzhou Youyi temi system controller
Technical parameters of pressure system:
1. Test load: commonly used 80kg (maximum 100kg)
2. Load resolution: 1 / 10000
3. Unit conversion: kg, LB, n
4. Load accuracy: FS ≤± 0.5%
5. Resolution: ± 0.5%
6. Displacement accuracy: ± 0.05mm
7. Speed range: 0.01 ~ 20mm / s, adjustable (common test speed: 0.1mm/s)
8. Effective stroke: 100mm
9. Test plane: 200X200mm (customizable)
10. Voltage collection range: 0 ~ 20V
11. Voltage resolution: 0.1mv
12. Voltage acquisition frequency: 100 times / S
13. Indenter size: 5x5x2mm or 10x10x2mm or 10x10x15mm
14. Indenter material: one piece of NBR and one piece of acrylic
15. Control system: PLC control
Specifications:
Specifications | Parameter |
Environmental requirements for equipment use | Temperature below 35 ℃, humidity below 80% |
Power Supply | AC220V,50/60Hz |
Source of water | Nothing |
Vcuum | Nothing |
Compressed air | Nothing |
Ground requirements and bearing requirements | Concrete ground, ≥ 600kg, |
Network requirements | Nothing |
Construction requirements for smoke, dust, waste gas and wastewater treatment plant | Exhaust gas discharge port diameter: 100mm |